ZYSNOR

Glossary · Construction and QS

What is Quantity Takeoff (QTO)? Meaning, Example and How It Works

By , Founder of ZYSNOR · Updated · Checked · 3 min read

In simple words

Quantity takeoff (QTO, also "taking off") is the process of measuring quantities, such as areas, lengths, volumes and counts, from drawings, models and specifications, mainly to work out construction cost. The word "takeoff" is also used for the list of quantities the process produces. Quantity surveyors and estimators do it.

Why it matters

The client's estimate, the contractor's tender and the site's material orders all rest on the same quantities. A complete, checked and traceable takeoff makes tenders comparable and later variations easy to value; a careless one is carried straight into the price and creates claims.

Types

  • Count (nr): doors, windows, sockets and sanitary fittings.
  • Length (m): skirting, pipes, kerbs and handrails.
  • Area (m²): plaster, paint, tiles and blockwork.
  • Volume (m³): concrete, excavation and fill.
  • Manual or digital: on dimension paper, on screen from PDF or CAD drawings, or extracted from a 3D BIM model. The tool changes; the measurement rules and the need to check do not.
Five boxes joined by arrows: drawings, dimension sheet, measure, square and bill
A takeoff moves from the drawings to priced bill items, and every number stays traceable.

Worked example

One room in a Lahore house: 5.00 m × 4.00 m, wall height 3.00 m, one door 0.90 × 2.10 m and one window 1.50 × 1.20 m.

Quantities taken off one room
Item Working Quantity
Floor area 5.00 × 4.00 20.00 m²
Perimeter 2 × (5.00 + 4.00) 18.00 m
Gross wall area 18.00 × 3.00 54.00 m²
Openings 1.89 + 1.80 3.69 m²
Net wall area 54.00 − 3.69 50.31 m²
Skirting 18.00 − 0.90 (door) 17.10 m
Doors, windows counted 1 nr each

Both openings are over 1.00 m², so they are deducted under the usual finishes rule; small openings may be kept, depending on the method of measurement the contract names.

Bar chart: gross wall 54.00 m², openings 3.69 m², net wall area 50.31 m²
Net wall area = 54.00 − 3.69 = 50.31 m².

Common mistakes

  • Measuring to the wrong face of a wall, or double counting at corners.
  • Forgetting to deduct openings, or deducting openings the rules say to keep.
  • Using the wrong drawing scale or an old revision.
  • Mixing units, such as m² against m.
  • Trusting model quantities without checking how the model was built.

Related terms

Frequently asked questions

Can BIM do the takeoff automatically?

A model can produce quantities directly, but they are only as good as the model; they still need checking against the measurement rules.

What is the difference between a material takeoff and a quantity takeoff?

A material takeoff lists raw materials (bags of cement, blocks); a quantity takeoff lists measured work items (m² of blockwork).

What happens to the takeoff after measuring?

The quantities are grouped into items and collated into a bill of quantities that contractors price.

Sources

← All glossary terms